GENERAL
YORK Model DEG units are single package air conditioners with
gas heat designed for outdoor installation on a rooftop or a slab.
The units are completely assembled on rigid, permanently
attached base rails. All piping, refrigerant charge, and
electrical wiring is factory-installed and tested. The units
require only electric power, gas piping and duct connections
at the point of installation.
The gas-fired heaters have aluminized steel tubular heat
exchangers and spark ignition with intermittent pilot.
This appliance is not to be used for temporary heating of
buildings or structures under construction.
INSPECTION
As soon as a unit is received, it should be inspected for possible
damage during transit. If damage is evident, the extent of the
damage should be noted on the carrier's freight bill. A separate
request for inspection by the carrier's agent should be made in
writing. Refer to Form 50.15-NM for additional information.
REFERENCE
Additional information on the design, installation, operation
and service of this equipment is available in the following
reference forms:
55.70-N1 -General Installation
55.70-N2 -Pre-start & Post-start Check List
530.18-N1.2V -Economizer Accessory
530.18-N1.13V -Man. Outdoor Air Damper Accy 0-35%
530.18-N1.14V -Man. Outdoor Air Damper Accy 0-100%
530.18-N1.12V -Motorized Outdoor Air Damper Accy.
530.18-N1.8V -Coil Guard
530.18-N2.11V -Low NOx Accessory
530.18-N8.2V -High Altitude Accy. (Natural Gas)
530.18-N8.3V -High Altitude Accy. (Propane)
530.18-N8.4V -Gas Piping Accessory
530.18-N8.12V -Propane Conversion Accessory
690.15-N25V -Low Ambient Accessory
Renewal Parts:
Refer to Parts Manual for complete listing of replacement
parts on this equipment.
All forms referenced in this instruction may be ordered from:
Standard Register
Toll Free Tel.: 877-318-9675
Fax: 877-379-7920
APPROVALS
Design certified by CGA and UL listed as follows:
1. For use as a forced air furnace with cooling unit.
2. For outdoor installation only.
3. For installation directly on combustible flooring or, in the U.S.A.,
on wood flooring or Class A, B, or C roof covering material.
4. For use with natural gas and/or propane (LP) gas.
Not suitable for use with conventional venting systems.

SUNLINE PLUS
GAS / ELECTRIC
SINGLE PACKAGE AIR CONDITIONERS
INSTALLATION INSTRUCTION
Supersedes: 035-14832-002-A-0302
035-14832-003-A-0204
MODELS D2EG 048 & 060 and D3EG 036
(11 SEER)
Installer should pay particular attention to the words: NOTE, CAUTION and WARNING. Notes are intended to clarify or make
the installation easier. Cautions
are given to prevent equipment damage. Warnings are given to alert installer that personal in
-
jury and/or equipment damage may result if installation procedure is not handled properly.
FOR YOUR SAFETY
Do not store or use gasoline or
other flammable vapors or liquids
in the vicinity of this or any other
appliance.
If you smell gas:
1. Open windows
2. Don't touch electrical switches.
3. Extinguish any open flame.
4. Immediately call your gas supplier.
CAUTION
THIS PRODUCT MUST BE INSTALLED IN STRICT COMPLIANCE WITH THE ENCLOSED INSTALLATION INSTRUC
-
TIONS AND ANY APPLICABLE LOCAL, STATE, AND NATIONAL CODES INCLUDING, BUT NOT LIMITED TO, BUILDING,
ELECTRICAL, AND MECHANICAL CODES
WARNING
INCORRECT INSTALLATION MAY CREATE A CONDITION WHERE THE OPERATION OF THE PRODUCT COULD
CAUSE PERSONAL INJURY, PROPERTY DAMAGE AND/OR DEATH.
WARNING
DE-ENERGIZE THE ELECTRICAL POWER AND TURN OFF THE GAS SUPPLY TO THE UNIT BEFORE ATTEMPTING TO
INSPECT, REPAIR OR PERFORM MAINTENANCE TO THE UNIT.
Przeglądanie stron 0
1 2 3 4 5 6 ... 19 20

Podsumowanie treści

Strona 1 - INSTALLATION INSTRUCTION

GENERALYORK Model DEG units are single package air conditioners withgas heat designed for outdoor installation on a rooftop or a slab.The units are co

Strona 2 - TABLE OF CONTENTS

10 Unitary Products Group035-14832-003-A-0204TABLE 7 - SUPPLY AIR PERFORMANCE - 5 Ton w/Belt-Drive BlowerMODELDEGAIR FLOWCFMAvailable External Static

Strona 3 - INSTALLATION

Unitary Products Group 11035-14832-003-A-0204MODELDEGPOWERSUPPLYVOLTAGELIMITATIONS(SEE NOTE 1)COMPRESSORCOND.FANMOTOR,FLASUPPLYAIRBLOWERMOTOR,FLAMINIM

Strona 4

12 Unitary Products Group035-14832-003-A-0204FIG. 9 - DIMENSIONS AND CLEARANCES (3, 4 & 5 TON)All dimensions are in inches. They aresubject to cha

Strona 5 - TABLE 3 - PIPE SIZING

COOLING SYSTEMThe cooling section is a complete factory package utilizing anair-cooled condenser. The system is factory-charged withRefrigerant-22.The

Strona 6 - 6 Unitary Products Group

SAFETY CONTROLS (Heating)The control circuit includes the following safety controls:1. Limit Control (LS).This control is located inside the heatexcha

Strona 7 - OPTIONAL ECONOMIZER RAIN HOOD

PILOT CHECKOUTThe pilot flame should envelope 3/8 inches of the end of theflame sensor. Refer to Figure 12. To adjust pilot flame, (1)remove pilot adj

Strona 8 - (SEE NOTE)

NOTE: The tubes must be inserted and held in a position per-pendicular to the air flow so that velocity pressure willnot affect the static pressure re

Strona 9

NORMAL MAINTENANCECAUTION: Prior to any of the following maintenance proce-dures, shut off all power to the unit to prevent per-sonal injury.Periodic

Strona 10

WARNING:Troubleshooting of components necessarily re-quires opening the electrical control box with thepower connected to the unit. Use extreme carewh

Strona 11

6. The pilot burner ignites but the sparker continues to sparkand the main burners do not ignite.a. Make the same checks and adjustments as describedi

Strona 12 - CLEARANCES

035-14832-003-A-02042 Unitary Products GroupGeneral...1Inspection...

Strona 13 - OPERATION

035-14832-003-A-0204Supersedes: 035-14832-002-A-0302Unitary Products Group5005 York Drive, Norman Oklahoma 73069Subject to change without notice. Pr

Strona 14 - START-UP

LIMITATIONSThese units must be installed in accordance with the currentedition of the following national and local safety codes:In the U.S.A.:1. Natio

Strona 15

The supply and return air duct systems should be designed for theCFM and static requirements of the job. They should NOTbesized to match the dimension

Strona 16 - WITHOUT AIR FILTERS

DISCONNECT SWITCH BRACKET FOR UNITSWITH OPTIONAL BELT-DRIVE BRACKETA special bracket for mounting a field-supplied disconnectswitch is provided in eac

Strona 17 - MAINTENANCE

GAS CONNECTIONThe gas supply line can be routed through the knockoutslocated on the front of the unit or through the opening providedin the unit'

Strona 18 - TROUBLESHOOTING

VENT AND COMBUSTION AIR HOODSThe vent and combustion air hoods are shipped attached to theblower housing in the blower compartment. These hoods mustbe

Strona 19 - TROUBLESHOOTING - Continued

NOTE: Install filters so that “Air Flow” arrows point toward theunit.8. Install filter cover over the end of the hood with one screw(center of hood),